Stai utilizzando un browser obsoleto. Si prega di aggiornare il browser per visualizzare correttamente la pagina.
Consegna il prossimo giorno lavorativo
Il diritto di restituzione scade dopo 15 giorni
Double differential temperature controller for one or two heat sources and one or two hot-water storage tanks. The controller can be used for the combination of a solid-fuel boiler with buffer and solar system...
Tutte le informazioni sul prodotto FornituraHigh Quality
Double differential temperature controller for one or two heat sources and one or two hot-water storage tanks. The controller can be used for the combination of a solid-fuel boiler with buffer and solar system. It is also possible to control solar systems of different roof orientations or charging two storage tanks. A circulation pump in the system can be speed-controlled via a PWM signal.
The CETA differential temperature controller has four relay outputs, four sensor inputs and a clear LC display. The controller is suitable for wall or DIN-rail mounting. An extension to up to four controllers via data bus is just as possible as heat balancing via an optional return sensor.
Fornitura: | |||
1 x | CETA 103 controller | ||
2 x | sonda collettore PT 1000/6 | ||
1 x | Immersion sensor KVT 20/2/6 | ||
1 x | materiale per montaggio |
Per ulteriori informazioni consultare Download
Codice OEG | 211211237 |
Contatto di commutazione: | 4 |
Quantità ingressi sonda: | 4 |
Type: | Differential temperature controller |
Type: | CETA 103 |
Function: | Heat balancing, Burner blocking, Differential control, PWM/ 0-10V signal, Tank-charging switchover |
Tensione [V]: | 230 |
Potenza assorbita [W]: | 2,1 |
Temperaturaambiente [°C]: | -10 .. 50 |
Tipo di sicurezza [IP]: |
IP30 |
Lunghezza x larghezza x altezza [mm]: | 145,5 x 48 x 161 |
Tipo di raccordo: | Morsetti isolanti |
Messa in sicurezza [A]: | 6,3 |
Peso [kg] | 0,42 |
Avvisi |
High Quality |
Codice doganale | 90328100 |
Ik zoek een regelaar om met PVT-panelen een buffervat op temperatuur te houden. Als het betrekkelijk zonnig en warm is zou de pomp moeten moduleren om een delta T van 4K te maken. Als de onderste temperatuur in het vat onder een bepaalde temperatuur komt, zou de pomp moeten moduleren om zo veel mogelijk energie naar het vat te krijgen. Is deze geschikt of zouden jullie een ander aanraden
Verwijst de pomp werkelijk naar de differentiële regelaar EBV heating circuit controller CETA 103 with PWM / 0 to 10 V control of naar iets anders?
EBV heating circuit controller CETA 103 with PWM / 0 to 10 V control: Instelbereik (uitschakelverschil + 3K) ... 30K