You are using an outdated browser. Please update your browser now to display the page correctly.
Delivery the next working day
Right of return 14 days
Premium solar storage tank for heating domestic hot water with boilers and low-temperature heating systems, especially for the additional connection of a solar thermal system.
The third smooth-pipe...
Premium solar storage tank for heating domestic hot water with boilers and low-temperature heating systems, especially for the additional connection of a solar thermal system.
The third smooth-pipe heat exchanger can be used optimally for return flow boosting.
The storage tank is used for new installations, but also very frequently as a replacement cylinder. Thanks to the various coating colours available and the wide range of connection options, it can be combined with heat generators and solar thermal systems from almost all manufacturers.
The inner surface of the cylinder has a high-quality enamel coating for hygienic DHW heating. The generously dimensioned heat exchanger surface of the lower smooth-pipe heat exchanger extends to the bottom of the cylinder, thus, ensuring a high energy advantage over many other products on the market.
The service hatch makes it easy to maintain and clean the cylinder.
For more information see Downloads
OEG no. | 516005240 |
Installation type: | Vertical storage tank |
Manufacturer | OEG |
EAN | 4055668014896 |
Energy efficiency class | A+ |
ErP-Label | |
Notes | |
Customs tariff number | 84191900 |
Colour: | silver |
Insulation according to DIN 4102-1 Fire Protection Class B2: | solid foamed insulation |
Weight [kg]: | 110 |
Total height including insulation [mm]: | 1750 |
Diameter with insulation [mm]: | 610 |
Tilt height [mm]: | 1830 |
Energy efficiency class according to EU regulation no. 812/2013: | A+ |
Heat retaining loss according to EN 12897 [W]: | 36 |
Heat losses in stand-by mode according to DIN 12897 [kW/h / 24 h]: | 0,864 |
Output capacity (45°C) [l]: | 471 |
Performance indicator NL following DIN 4708: | 10 |
TÜV certificate ID: | 0000080165 |
Real volume according to EN 12897 [l]: | 292 |
pmax Tank [bar]: | 10 |
tmax Tank [°C]: | 95 |
tmin Tank [°C]: | 20 |
Smooth-pipe heat exchanger [number]: | 2 |
Smooth-pipe heat exchanger area bottom [m²]: | 1,15 |
Smooth-pipe heat exchanger area top [m²]: | 0,77 |
Smooth-pipe heat exchanger volume bottom: | 7,50 |
Smooth-pipe heat exchanger volume top: | 5,05 |
pmax Smooth-pipe heat exchanger [bar]: | 10 |
tmax Smooth-pipe heat exchanger [°C]: | 130 |
Connection layout: | 180° |
Connection sensor [Ø mm / terminal]: | 6 mm |
Connection cold / hot water: | R 1" |
Connection heat exchanger [thread]: | Rp 1" |
Connection circulation: | R 3/4" |
Connection heating element [thread]: | Rp 1 1/2" |
Service hatch (LK 150): | 115 / 180 |
Max. immersion depth of flange heater [mm]: | 420 |
Max. immersion depth of screw-in heater [mm]: | 500 |
Die Gesamthöhe inklusive Dämmung liegt bei 1.750 mm und der Durchmesser inklusive Dämmung liegt bei 640 mm.
Ja das ist richitg. Die Trinkwasseranschlüsse sind mit Außengewinde und die für Heizungs-/ Solaranschlüsse sind mit Innengewinde.
Die Glattrohrwärmetauscher sind aus Stahl P235TR1.
Diamètre avec isolation: 640 mm
Hauteur totale avec isolation: 1750 mm
Bonjour,
Oui, ce ballon peut recevoir une résistance électrique.
Cordialement,
Votre équipe OEG
Nous n'avons pas d´indication sur la puissance en kw des échangeurs. Au contraire, le débit de soutirage est décisif.
Bonjour,
L'anode Magnesium anode Ø 33 x 700 mm 1 1/4" screw-in thread est installée dans les ballons.
700 x Ø33 mm DN32, 1 1/4"
Cordialement,
Votre équipe OEG
Bonjour, vous avez écrit "Indication: Tous les préparateurs d'eau chaude sanitaire OEG sont équipés d'un raccord de 1 1/2'' pour une résistance électrique (Rp 1 1/2'')". Je ne retrouve pas ce raccord dans la nouvelle documentation sous download. Faut-il passer par la trappe de visite/bride ?
Bonjour,
Il est possible de mettre une résistance électrique par la bride de revision.
Cordialement,
Votre équipe OEG
c'est bien marqué sur les pages correspondantes dans notre catalogue
Deze gegevens kunt u in het download gedeelte van dit product terugvinden.
U dient hiervoor wel ingelogd te zijn.
Guten Tag,
eine Opferanode sollte alle 2 - 3 Jahre geprüft werden. Man muss die Opferanode nach 5 - 7 Jahren austauschen.Es kommt auf die Wasserqualität an, wie schnell sich die Anode zersetzt oder auch nicht. Es gibt 2 Methoden eine Anode zu prüfen.
1. Ausbauen und durch Sichtkontrolle prüfen, ob diese noch komplett vorhanden ist.
2.Über die Leitfähigkeit des Wasser den Strom messen.
Dazu benötigen Sie: Anode tester AT1Anode tester AT1Die Speicheranschlüsse sind alle mit Innengewinde gefertigt.
Kaltwasser:1" IG
Warmwasser: 1" IG
einen schönen Tag wünscht das OEG TEAM
La date de validité des promotions est inscrite sur la promotion.
5 cm
Bonjour,
Vous trouverez ces indications dans la rubrique Download.
Hauteur 400 mm et 1350 mm.
Cordialement,
Votre équipe OEG
par exemple Screw-in heater 3.0 kW