Solenoid valve GSR E 4323/1001/.012 1/2" 230V 50 Hz

OEG no.: 113123450
Zoom Solenoid valve GSR E 4323/1001/.012 1/2"  230V  50 Hz
OEG no. : 113123450

2/2 solenoid valves
Positively controlled
Closed in a de-energized state
Fields of application:
2/2 way solenoid valves of the series 43 can be used in closed circuits since the valves work...

All product information Scope of delivery
Related products
Wipe 'n' Buy ®
Wipe 'n' Buy

2/2 solenoid valves
Positively controlled
Closed in a de-energized state
Fields of application:
2/2 way solenoid valves of the series 43 can be used in closed circuits since the valves work without a pressure difference because of the
positively controlled diaphragm. Typical fields of application are HVAC and general mechanical engineering.
Type of protection IP65. Installation only with upright magnets!
Delivered with connector plug.
Solenoid coils 012 / T012
012/T012 coils correspond to VDE 0580.
Power consumption: approx. 43/24 VA
Rel. duty time: 100 %
Operating voltage: +5 / -10 %
Possible coil voltages:
24 V =, 24 V, 42 V, 230 V ~ (50 Hz + 60 Hz)


Media: Air, water, neutral gases
Temperature: -10 - +90°C
Seal material: NBR


Media: Water, hot water, vapour
Temperature: -10 - +130°C
Seal material: EPDM design-TM


Media: Oil (also synthetic), fuel
Temperature: -10 - +100°C
Seal material: FKM


Ambient temperature: -10°C / +35°C
Viscosity: max. 22 mm²/s-1
Burst pressure: > 60 bar


Scope of delivery:
1 xsolenoid valve
1 xappliance plug

For more information see Downloads


OEG no. 113123450
Model: Normally closed (NC)
Housing: Brass 2.0402
Voltage [V]: 230V / 50Hz
Connection: 1/2"
Protection type [IP]:
IP65

IP65

IP65
kv-value: 3.9 m³/h
Ambient temperature [°C]: -10 .. 50
Power consumption [W]: 18
Viscosity: Max. 22 mm²/s-1
Seal: NBR
Pressure [bar]: 0 - 16
Media temperature [°C]: -10 .. 80
Weight [kg] 0.68
Customs tariff number 84818087
en
Question:

bonjour ,cette électrovanne peut elle servir pour la supression d'un compresseur merci

Answer OEG:

Bonjour,

Oui, l'électrovanne peut commuter une plage de pression de -0,9 à 16 bar, c'est-à-dire également du vide jusqu'à -0,9 bar.

en
Question:

"Einbau nur mit stehenden Magneten" was bedeutet das? Vertikal / Horizontal?

Answer OEG:

Guten Morgen,

der Einbau des Magnetventils darf lediglich horizontal (wagerecht) erfolgen.