Delivery the next working day
Right of return 14 days
Premium REVERSE+ heat pump combination storage tank, which can be used for cooling and heating in addition to DHW heating. The large heat exchanger surface of the double coil is specially designed...
All product informationPremium REVERSE+ heat pump combination storage tank, which can be used for cooling and heating in addition to DHW heating. The large heat exchanger surface of the double coil is specially designed for heating and supplying domestic hot water in combination with heat pumps and solar thermal systems. The additional buffer storage tank increases the volume of the heating circuit and, thus, avoids cycling of the heat pump. The buffer area is thermally separated from the DHW area and can therefore be used independently for cooling or heating surface heating systems.
In order to protect the cylinder surface from condensate during the cooling function, the cylinder is equipped with a special, high-quality anti-corrosion coating. As condensation can form at cooling temperatures in conjunction with higher ambient temperatures, it is necessary to specially protect the system components involved. The high-quality A⁺ insulation of OEG also ensures the lowest temperature losses with these storage tanks.
To supplement the heat pump heating system, it is possible to operate an optional immersion heater in both the DHW cylinder and the buffer cylinder below.
For more information see Downloads
OEG no. | 516005668 |
Smooth-pipe heat exchanger: | 2 |
Recommended for: | Heat pumps |
Installation type: | Vertical storage tank |
Manufacturer | OEG |
Brand | Reverse+ |
Energy efficiency class | A+ |
ErP-Label | |
Notes | |
Customs tariff number | 84191900 |
Colour: | white |
Insulation according to DIN 4102-1 Fire Protection Class B2: | solid foamed insulation |
Weight [kg]: | 155 |
Total height including insulation [mm]: | 1540 |
Diameter with insulation [mm]: | 760 |
Tilt height [mm]: | 1710 |
Energy efficiency class according to EU regulation no. 812/2013: | A+ |
Heat retaining loss according to EN 12897 [W]: | 39 |
Heat losses in stand-by mode according to DIN 12897 [kW/h / 24 h]: | 0,936 |
Output capacity (45°C) [l]: | 439 |
Performance indicator NL following DIN 4708: | 9 |
Real volume according to EN 12897 [l]: | 400 |
pmax Tank [bar]: | 3 |
tmax Tank [°C]: | 95 |
tmin Tank [°C]: | 10 |
tmax Ambient air [°C]: | 30 |
Max. rel. air humidity [%]: | 80 |
Buffet storage tank capacity (part of the actual capacity) [l]: | 100 |
Domestic hot water tank volume (Part of the real volume) [l]: | 300 |
pmax Domestic hot water tank [bar]: | 10 |
tmax Domestic hot water tank [°C]: | 95 |
Smooth-pipe heat exchanger [number]: | 2 |
Smooth-pipe heat exchanger area bottom [m²]: | 1 |
Smooth-pipe heat exchanger area top [m²]: | 1,20 |
Smooth-pipe heat exchanger volume bottom: | 6 |
Smooth-pipe heat exchanger volume top: | 8 |
pmax Smooth-pipe heat exchanger [bar]: | 10 |
tmax Smooth-pipe heat exchanger [°C]: | 130 |
Connection layout: | 180° |
Connection sensor [Ø mm / terminal]: | 6 mm |
Connection cold / hot water: | R 1" |
Connection heat generator [thread]: | lower R 1" / uper Rp 1 1/2" |
Connection heat exchanger [thread]: | Rp 1" |
Connection circulation: | R 3/4" |
Connection heating element [thread]: | Rp 1 1/2" |
Service hatch (LK 150): | 115 / 180 |
Max. immersion depth of flange heater [mm]: | 540 |
Max. immersion depth of screw-in heater [mm]: | 600 |
OEG no. | 516005668 |
Smooth-pipe heat exchanger: | 2 |
Recommended for: | Heat pumps |
Installation type: | Vertical storage tank |
Brand | Reverse+ |
Notes | |
Customs tariff number | 84191900 |
Rated volume according to EN 12897: | 400 |
Colour: | white |
Insulation according to DIN 4102-1 Fire Protection Class B2: | solid foamed insulation |
Weight [kg]: | 155 |
Total height including insulation [mm]: | 1540 |
Diameter with insulation [mm]: | 760 |
Tilt height [mm]: | 1710 |
Energy efficiency class according to EU regulation no. 812/2013: | A+ |
Heat retaining loss according to EN 12897 [W]: | 39 |
Heat losses in stand-by mode according to DIN 12897 [kW/h / 24 h]: | 0,936 |
Output capacity (45°C) [l]: | 439 |
Performance indicator NL following DIN 4708: | 9 |
Real volume according to EN 12897 [l]: | 400 |
pmax Tank [bar]: | 3 |
tmax Tank [°C]: | 95 |
tmin Tank [°C]: | 10 |
tmax Ambient air [°C]: | 30 |
Max. rel. air humidity [%]: | 80 |
Buffet storage tank capacity (part of the actual capacity) [l]: | 100 |
Domestic hot water tank volume (Part of the real volume) [l]: | 300 |
pmax Domestic hot water tank [bar]: | 10 |
tmax Domestic hot water tank [°C]: | 95 |
Smooth-pipe heat exchanger [number]: | 2 |
Smooth-pipe heat exchanger area bottom [m²]: | 1 |
Smooth-pipe heat exchanger area top [m²]: | 1,20 |
Smooth-pipe heat exchanger volume bottom: | 6 |
Smooth-pipe heat exchanger volume top: | 8 |
pmax Smooth-pipe heat exchanger [bar]: | 10 |
tmax Smooth-pipe heat exchanger [°C]: | 130 |
Connection layout: | 180° |
Connection sensor [Ø mm / terminal]: | 6 mm |
Connection cold / hot water: | R 1" |
Connection heat generator [thread]: | lower R 1" / uper Rp 1 1/2" |
Connection heat exchanger [thread]: | Rp 1" |
Connection circulation: | R 3/4" |
Connection heating element [thread]: | Rp 1 1/2" |
Service hatch (LK 150): | 115 / 180 |
Max. immersion depth of flange heater [mm]: | 540 |
Max. immersion depth of screw-in heater [mm]: | 600 |
Alle beschikbare documenten zijn te vinden in de downloads van het artikel.