Hot-water storage tanks for heating up domestic water by means of boilers and low-temperature systems of all manufacturers.
The inner surface of the storage tank is coated with a high-quality enamelling...
Hot-water storage tanks for heating up domestic water by means of boilers and low-temperature systems of all manufacturers.
The inner surface of the storage tank is coated with a high-quality enamelling. The generously dimensioned heat exchanger surface that reaches down to the bottom ensures excellent heat transmission. A laterally positioned service hatch makes it possible to maintain and clean the storage tank conveniently, and it can be fitted with an electric heating element if required. The unrivalled OEG vacuum insulation of the storage tanks ensures there are significantly lower heat losses than the insulations of customary storage tanks.
For more information see Downloads
OEG no. | 516005206 |
Installation type: | Vertical storage tank |
Manufacturer | OEG |
Energy efficiency class | A+ |
ErP-Label | |
Notes | |
Customs tariff number | 84191900 |
Colour: | silver |
Insulation according to DIN 4102-1 Fire Protection Class B2: | solid foamed insulation |
Weight [kg]: | 150 |
Total height including insulation [mm]: | 1770 |
Diameter with insulation [mm]: | 760 |
Tilt height [mm]: | 1915 |
Energy efficiency class according to EU regulation no. 812/2013: | A+ |
Heat retaining loss according to EN 12897 [W]: | 43 |
Heat losses in stand-by mode according to DIN 12897 [kW/h / 24 h]: | 1,032 |
Output capacity (45°C) [l]: | 785 |
Performance indicator NL following DIN 4708: | 19 |
TÜV certificate ID: | 0000080165 |
Real volume according to EN 12897 [l]: | 507 |
pmax Tank [bar]: | 10 |
tmax Tank [°C]: | 95 |
tmin Tank [°C]: | 20 |
Smooth-pipe heat exchanger [number]: | 1 |
Smooth-pipe heat exchanger area bottom [m²]: | 1,88 |
Smooth-pipe heat exchanger volume bottom: | 12 |
pmax Smooth-pipe heat exchanger [bar]: | 10 |
tmax Smooth-pipe heat exchanger [°C]: | 130 |
Connection layout: | 180° |
Connection sensor [Ø mm / terminal]: | 6 mm |
Connection cold / hot water: | R 1" |
Connection heat exchanger [thread]: | Rp 1" |
Connection circulation: | R 3/4" |
Connection heating element [thread]: | Rp 1 1/2" |
Service hatch (LK 150): | 115 / 180 |
Max. immersion depth of flange heater [mm]: | 540 |
Max. immersion depth of screw-in heater [mm]: | 600 |
Is for storage tank 516005206 insulation made like removable, with insulation with segments or this is not removable?
Hello,
the insulation is not removable in this accumulator.
With kind regards
E.e.a. is afhankelijk van het vermogen.
OEG heeft een speciale warmtepompboiler (DHW storage tank 500 l with 2 smooth-pipe heat exchangers)
Eventueel is het ook mogelijk om een tapwaterboiler te gebruiken met 2 buiswisselaars en deze door te lussen om daarmee een groter warmtewisselaar oppervlak te creeeren. (Solar storage tank TWS 500-2 with 2 smooth-pipe heat exchangers)
Bonjour, vous donnez une côte de basculement de 1910mm mais qu'en est-il de la distance au plafond nécessaire pour changer l'anode? Il me semble qu'elle est assez longue et il faut plus que ça pour la sortir. Une personne a reçu le ballon sans joint de trappe, elle n'est pas montée par défaut à la livraison? (Je n'ai pas de résistance électrique à monter). Cordialement
Bonjour,
L'anode n'est jamais incluse dans la mesure de l'inclinaison....
Le ballon a deux anodes, sur le dessus Magnesium anode Ø 33 x 700 mm 1 1/4" screw-in thread (1 1/4" 700mm), à remplacer si nécessaire par une anode enchaînée ou une anode à courant imposé s'il y a des problèmes d'espace. Une anode n° Magnesium anode for insulated installation 500 x Ø 33 mm M8 x 30 (M8, 500 mm) se trouve dans le couvercle de la trappe de visite.
Le joint de couvercle Flange cover gasket Ø 175 x 115 x 3 mm s'adapte, que nous n'avons pas seulement utilisé pour l'application d'une résistance électrique. Il doit toujours être installé, sinon le ballon ne serait jamais étanche.
Cordialement,
Votre équipe OEG
Bonjour,
Oui, nous pouvons fabriquer un tel ballon sur mesure.
Nous vous enverrons le formulaire à remplir par mail.
Cordialement,
Votre équipe OEG
Bonjour je vient de vous acheter un preparateur d'eau potable 516005206 il ma etais livrer sans joint de la trape du bas pouvez vous me donner le code car le ballon n'est pas etanche merci
Flange cover gasket Ø 175 x 115 x 3 mm
envoyé par mail