Heating circuit set mixed circuit 4-way with pump CPA-E 55/25 incl. actuator

OEG no.: 512245116
Zoom Heating circuit set mixed circuit 4-way with pump CPA-E 55/25 incl. actuator
OEG no. : 512245116

The 4-way mixer with OEG actuator STM allows to simultaneously regulate the flow temperature of the heating circuit and also the temperature on the boiler inlet side by mixing the water from the hot...

All product information Scope of delivery
Wipe 'n' Buy ®
Wipe 'n' Buy

The 4-way mixer with OEG actuator STM allows to simultaneously regulate the flow temperature of the heating circuit and also the temperature on the boiler inlet side by mixing the water from the hot inlet flow and the cooled-down return flow in conjunction with an external controller.
This prevents condensation or is used as return rise with solid-fuel boilers.
The OEG high-efficiency pump CPA-E 55/25-130 transports the water from the heat generator to the consumers. The integrated thermometers allow for an easy visual inspection of the function.
Thanks to the ball valves, maintenance of the pump and the heating and boiler circuit is possible without shutting down the complete system.
Insulation reduces the heat losses to the environment.

Inlet flow:
• 1x OEG heating circulation pump CPA-E 55/25-130
• 1x shut-off ball valve with integrated thermoeter (red)

Return flow:
• 1x shut-pff ball valve with integrated thermometer (blue)
• 1x check valve
• 1x copper pipe DN 25

OEG actuator STM:
• Torque: 5 NM
• Run-time 90°: 2 minutes
• Voltage: 230 V, 50 Hz

 

 


Scope of delivery:
1 x4-way mixing valve
1 xActuator
1 xcirculation pump
2 xBall valve
2 xthermometer
1 xreturn pipe
1 xWall bracket
1 xinsulation
1 xGravity brake

OEG no. 512245116
Nominal size: DN25
Axial dimension: 125
Dimensions: 470 x 290 x 180 mm
Connection heating circuit: 1" IT
Connection boiler circuit: 1 1/4" ET
Pressure max. [bar]: 6
Manufacturer OEG
Weight [kg] 3.6
Customs tariff number 84136080 (EEC)
en
Question:

Bonjour Est ce qu il y a un schéma de branchement disponible Merci

Answer OEG:

Bonjour,

Pour l'instant, nous n'avons pas de schéma hydraulique.
Merci de nous dire ce que vous voulez faire avec le groupe de raccordement.
Nous pouvons vous proposer une alternative.

Cordialement,
Votre équipe OEG

You have to be logged in to ask a question

No customer reviews yet

In order to give a review, you have to be logged in.