Fresh-water storage tank for highest demands on drinking water hygiene and energy efficiency.
The structure of fresh-water storage tanks differs fundamentally from conventional, large-volume domestic hot water storage tanks...
Delivery by forwarding agency
High Quality
Clean fresh water generation in corrugated stainless steel pipe with flow heater principle
10-year warranty
TÜV Rheinland
Fresh-water storage tank for highest demands on drinking water hygiene and energy efficiency.
The structure of fresh-water storage tanks differs fundamentally from conventional, large-volume domestic hot water storage tanks. A built-in corrugated stainless steel pipe separates the drinking water from the heating water and also serves as a high-performance heat exchanger. This combines the advantages of a buffer storage tank with those of an instantaneous water heater.
The heating water serves as actual heat storage while the drinking water passes through the corrugated stainless steel pipe only if required and, this ensures a domestic water heating that is legionella-safe. You do not need a legionella protection programme in the control unit. At all times, the consumer is provided with hygienically perfect, fresh water at the desired temperature.
The additional smooth-pipe heat exchanger gives your customer the option of integrating an additional heat generator at any time and feeding its energy into the fresh-water storage tank.
For more information see Downloads
OEG no. | 516008270 |
Recommended max. number of persons for DHW: | 8 |
Installation type: | Vertical storage tank |
Manufacturer | OEG |
Brand | Pure+ |
Energy efficiency class | A+ |
ErP-Label | |
Notes | |
Customs tariff number | 84191900 |
Colour: | silver |
Insulation according to DIN 4102-1 Fire Protection Class B2: | solid foamed insulation |
Weight [kg]: | 134 |
Total height including insulation [mm]: | 1725 |
Diameter with insulation [mm]: | 710 |
Tilt height [mm]: | 1865 |
Energy efficiency class according to EU regulation no. 812/2013: | A+ |
Heat retaining loss according to EN 12897 [W]: | 40 |
Heat losses in stand-by mode according to DIN 12897 [kW/h / 24 h]: | 0,960 |
Output capacity (45°C) [l]: | 230 |
Performance indicator NL following DIN 4708: | 2 |
TÜV certificate ID: | 0000080330 |
Real volume according to EN 12897 [l]: | 413 |
pmax Tank [bar]: | 3 |
tmax Tank [°C]: | 95 |
tmin Tank [°C]: | 20 |
DHW heat exchanger area [m²]: | 6 |
DHW heat exchanger volume [l]: | 26,70 |
pmax DHW heat exchanger [bar]: | 6 |
tmax DHW heat exchanger [°C]: | 95 |
Smooth-pipe heat exchanger [number]: | 1 |
Smooth-pipe heat exchanger area bottom [m²]: | 1,88 |
Smooth-pipe heat exchanger volume bottom: | 12,30 |
pmax Smooth-pipe heat exchanger [bar]: | 10 |
tmax Smooth-pipe heat exchanger [°C]: | 130 |
Connection layout: | 180° |
Connection sensor [Ø mm / terminal]: | 6 mm |
Connection cold / hot water: | Rp 1 1/4" |
Connection heat generator [thread]: | R 1" |
Connection heat exchanger [thread]: | Rp 1" |
Connection heating element [thread]: | Rp 1 1/2" |
Max. immersion depth of screw-in heater [mm]: | 600 |
Vous pouvez brancher trois sondes au ballon. Vous trouverez un aperçu des raccordements à la page 63 de notre notice d´installation et d´emploi. Si le nombre de raccords disponibles n'est pas suffisant, merci de remplir le document "Demande de ballon spécial".
Omdat de verswaterboiler voor verschillende systemen kan worden gebruikt en er dan voldoende debiet beschikbaar is voor de toepassingen.
Ja, daar is deze zeer geschikt voor, de boiler is verkrijgbaar in complete sets, zie bijvoorbeeld Solar package with fresh-water storage tank 3 collector panels, Solar package with fresh-water storage tank 3 collector panels en Solar package with fresh-water storage tank 3 collector panels, deze staan ook al op de RVO ISDE lijst met nummer KA11525
Hallo, gibt es Hydraulikschemen zu diesen Speichern? Möchte den Speicher gerne als eine Art Wohnungsstation betreiben, d.h. mit einem Wärmemengenzähler in der Zuleitung nicht nur die Energie der Warmwasserbereitung, sondern auch den Wärmeverbrauch des Heizkreises zählen. Also entweder den Heizkessel am Glattrohrwärmetauscher anschließen und den Heizkreis (gemischt) VL an M bzw. N, RL an A, falls die Leistung des Wärmetauschers ausreicht, oder den Heizkessel an VL an M bzw. N, RL an A und davor ein Abgang für den Heizkreis. Ich habe im Bestand nur eine Zuleitung (VL, RL) und über die muss ich den Heizkreis betreiben und den Friwa-Speicher anschließen. Da mein Heizkreis gemischt ist, spielen die 65°C im Speicher keine Rolle für meinen Heizkreis. Die Schüttleistung beim 400 Ltr. Speicher bedeutet dass der Speicher wenn er auf 65°C aufgeheizt ist 230 Ltr. Warmwasser mit 45°C ausschüttet ohne dass der Speicher in dieser Zeit nachgeheizt werden muss? Realistisch betrachtet wird der Speicher kaum oben und unten genau 65°C haben. Gibt es vielleicht auch Angaben wenn der Speicher weniger als 65°C hat? Da ich meine vier Wohneinheiten wegen der zu geringen Durchmesser der Heizungsleitungen (Bestand) nicht mit Wohnungsstationen betreiben kann, habe ich vor mir insges. vier Frischwasserspeicher in die jeweiligen Einheiten zu stellen und diese mit meinem Pelletkessel 24 kW und dem vorhandenen 1500 Ltr. Pufferspeicher zu beladen. Durch das Puffervolumen der Frischwasserspeicher muss ich bei Warmwasserentnahme nicht akut mit 30/40 kW nachheizen wie bei der Wohnungsstation, weil das eben meine Zuleitungen nicht hergeben. Für die Beantwortung der vielen, nicht ganz gewöhnlichen Fragen bedanke ich mich im Voraus. Johannes Scheibmaier
Schema wurde em Kunden per Mail zugeschickt.
Hoe de boiler word aangesloten, vind uw in de installatie- en bedieningsinstructie. (Download onlineshop)
merci de verfiier Fresh-water storage tank 400 litres with 2 smooth pipe heat exchangers
Bonjour,
Vous trouverez ces informations dans la fiche technique du ballon dans la rubrique Download.
Surface de l'échangeur thermique eau sanitaire: 6 m²
Surface de l'échangeur thermique à tube lisse: 1,8 m² en bas, 1,5 m² en haut
Cordialement,
Votre équipe OEG